Skip to content

3.3 RC Parameter Identification Validation

The parameter identification page estimates the RC model parameters.

Validation Steps

  1. Open the RC parameter identification view.
  2. Check that the fitting routine runs successfully.
  3. Review the identified parameter values for R0, R1, R2, C1, and C2.
  4. Confirm that the identified values are positive and physically reasonable.

Expected Result

The software should produce a full set of ECM parameters.

Acceptance Check

  • R0, R1, R2, C1, and C2 are all generated.
  • Values are positive and do not show unrealistic spikes.
  • The user can continue to the pulse fit validation step.